Field Office Compliance - Field Activity - 40362


CORN LP - 310657526
1303 Highway 3 e Goldfield, IA 50542
Wright County

FO 2

Activity Report
Document Name Type File Date Note
CORN LP - Goldfield (2011-05-03) Air Quality Inspection.pdf
Inspection Report (public)
05/03/2011 AQ Inspection Report
File Name File Type File Date Note
Comments
5/3/2011 1) Need to request TV Permit modification to change emission point characteristics for S120 as TV permit incorrectly identifies stack as having a vertical, unobstructed discharge. The last two construction permit supplements for this EP have correctly identified the discharge as horizontal. 2) Need to check on applicability of Subpart VVa with regard to three new valves which replaced connections. The original connections were installed prior to 2006 and were therefore not subject to VVa; however, the new valves obviously are post-2006. TRENT LAMBERT
Compliance Tracking
Action Type Date Completed Date Comment Delete
"
"