Field Office Compliance - Assistance


Assistance ID - 79698
IPL - Ottumwa Generating Station- Switchgrass Processing Facility - 318511125
20775 Power Plant Road Chillicothe, IA 52501
Wapello County

FO 6

Report
File Name File Type File Date Note
Comments
7/2/2015 Rob called to request assistance in identifying a situation regarding reporting an excess emission event. Rob said that an Alliant employee reported seeing a puff of visible emissions off a lime storage silo during pneumatic filling from a vender filling the silo via semi. Likely the driver over pressurized the small bin vent filter and hence blew material out for a brief period of time. I asked if Rob would quantify it, and he said no as he didn't see the puff himself. I explained that while this situation could be reportable, that i'd recommend having a discussion with the vendor and to post a sign at the silo so the future truck driver/delivery people don't make the same mistake. So in essence, i told him to not report this anomoly as an EE, but rather use it to educate future truck drivers. He said he would call the vendor and post a sign at the silo hookup and ground level. KURT LEVETZOW