1/6/2011 On Thursday, 1-6-2011, Washington City Engineer, Rob McDonald stopped at the field office to discuss a couple wastewater problems. The first involves an old field tile and several houses on the south end of town, near Halycon House. Apparently years ago, a farmer put in a field drain tile (5" clay tile) and tied it into a city manhole on the sanitary sewer since there was no where else to drain it to. Later, two houses tied their sanitary sewers into this line. It is not known whether or not these have septic tanks on their lines. The city recently did dye testing on these two houses and verified that their sewage goes to the city manhole. Mr. McDonald explained that the city has two routes of fixing this. They have to dye test some more houses further out. If these are hooked to the same field tile, the will have to replace the tile with a sewer line, since now it is a huge source of I/I to the system. If these two houses are the only ones on the field tile, they plan to install a new sewer line to serve these two and tie into the manhole and abandon the field tile - cut it off from the sanitary sewer. His question on these two houses was, that for the time being, is the discharge to the field tile allowable. I told him yes, since it is being conveyed to the sanitary sewer and that the field tile line itself is a source of I/I, but a separate issue. He aslo reported they are going to televise the lines from the two houses to determine if they have septic tanks. If they do, can they bypass the septic tanks and go to the field tile. Again, I responded this is OK since the field tile is basically a sanitary sewer. His second issue involves the styrofoam plant. They have noticed, because of steam coming from the storm water intake in the street, that the styrofoam plant has a discharge of clear water going to the storm sewer. Due to the steam, it is probably some type of cooling water. I told him that it should be going to the sanitary sewer unless it is completely untreated ground water. If they are using city water for cooling, there is chlorine and possibly pH issues with the dishcarge. The city will contact the industry and investigate further. [Editorial comment] the city is working to eliminate this old field tile which is a source of I/I to their system, while at the same time our rules are telling them they have to add this cooling water discharge to their system which is added hydraulic loading. PAUL BRANDT