Field Office Compliance - Assistance


Assistance ID - 136261
Boone City Of Stp - 310636881
1721 MCHOSE DRIVE Boone, IA 50036
Boone County

FO 5

Report
File Name File Type File Date Note
Comments
11/19/2025 JD wants to keep Agcertain as an individually permitted IU, but was concerned they didn't meet flow or loadings requirements. Their flow and loading is erratic. A new meter was installed and they discharge significantly less than used to be reported. I sent JD the following. pretreatment question Gastineau, Janet <[email protected]> 2:40?PM (0 minutes ago) to John Here you go...The bold language holds the key. 40 CFR 403.8(f)(1)(iii) - requires the control of significant industrial users through individual permits. 40 CFR 403.3(v) - defines significant industrial user 40 CFR 403.3(v)(ii) - "Any other Industrial User that: discharges an average of 25,000 gallons per day or more of process wastewater to the POTW (excluding sanitary, noncontact cooling and boiler blowdown wastewater); contributes a process wastestream which makes up 5 percent or more of the average dry weather hydraulic or organic capacity of the POTW Treatment plant; or is designated as such by the Control Authority on the basis that the Industrial User has a reasonable potential for adversely affecting the POTW's operation or for violating any Pretreatment Standard or requirement (in accordance with 40 CFR 403.8(f)(6)). https://www.ecfr.gov/current/title-40/chapter-I/subchapter-N/part-403 JANET GASTINEAU