The following projects are currently advertised for bids. Interested bidders may find general information about each project, as well as printable actual Contract Documents in PDF format. The general information is the same project description provided to Newspapers and by direct mail solicitations. The Contract Documents include the Drawings and the entire Project Manual. Drawings can be printed on any regular or large format printers. The Project Manual includes Proposal Forms, Front End Documents, General and Supplementary Covenants, and Technical specifications. All these are also completely printable.
Effective October 2009, the Department will no longer be responsible for providing hard copy notice to bidders or addenda to either contractors or plan rooms. An email listserv has been created to communicate electronically with vendors currently on file with the DNR. As a member of this listserv, you will receive electronic notice to bidder information on a regular basis.
To subscribe to this list, click here.
The Department will be utilizing the vendor Beeline and Blue to provide printed copies of Plans and Specifications and Addenda upon request. The department will no longer provide complimentary copies of Plans and Specifications to contractors or sub-contractors after award of the contract. Please visit dfs.beelineandblue.com/iowa or contact (515) 244-1611 for more information.
To access any of these, unless you have already done so, you will need to download and install Acrobat Reader from the Adobe Website.
You may obtain a free download from
Click on the project names below to view the one(s) which interest you.
This project upgrades the existing campground located at McIntosh Woods State Park and consists of removal of existing shower building, removal of existing gravel camp pads, removal/salvage of existing electric outlet boxes and hydrants, removal of existing trees that are in conflict within the work zone, install new gravel camp pads, electric services, water services, sanitary sewers and services, a new shower building and seeding and mulching all disturbed areas located at McIntosh Woods State Park in Cerro Gordo County, Iowa.
ESTIMATED QUANTITIES:
Demolition
1 L.S.
Clearing and Grubbing
1 L.S.
Tree Clearing
1 L.S.
Full Depth Saw Cut
372 L.F.
HMA Pavement Removal
604 S.Y.
PCC Removal
96 S.Y.
Gravel Pad Removal and Placement
3,970 S.Y.
Grading
1 L.S.
8-inch Filter Sock
1,050 L.F.
Sanitary Sewer Connection to Existing Structure
1 Each
Type SW-301 48" Diameter Sanitary Manhole w/Type 'A' Casting
19 Each
8-inch Sanitary Sewer (SDR 26)
2,455 L.F.
6-inch Sanitary Sewer (SDR 35)
176 L.F.
4-inch Sanitary Sewer Service PVC (SDR 35)
980 L.F.
RV Sanitary Sewer Cleanout Connection
37 Each
8"x6" PVC Schedule 40 Service Wye
1 Each
8"x4" PVC Schedule 40 Service Wye
28 Each
SW-203 Sanitary Sewer Cleanout
2 Each
1-inch HDPE Pipe SDR 11
1,110 L.F.
2-inch HDPE Pipe SDR 11
389 L.F.
3-inch HDPE Pipe SDR 11
2,220 L.F.
6-inch PVC Pipe SDR 18
270 L.F.
2-Inch Valve with Valve Box
2 Each
3-Inch Ball Valve with Valve Box
5 Each
EJ 6-inch Ductile Iron Gate Valve with Valve Box
3 Each
10"x10"x6" Ductile Iron Tapping Tee
1 Each
6"x6"x6" PVC SDR 18 TEE
1 Each
2"x2"x1" HDPE SDR 11 Tee
4 Each
2"x2"x2" HDPE SDR 11 Tee
2 Each
3"x3"x1" HDPE SDR 11 Tee
31 Each
3"x3"x2" HDPE SDR 11 Tee
1 Each
3"x3"x3" HDPE SDR 11 Tee
2 Each
2"x1" HDPE Reducer
2 Each
6"x3" HDPE Reducer
1 Each
EJ Fire Hydrant with Curb Stop
1 Each
Yard Hydrant with Curb Stop
37 Each
2" PVC Watertight
1 Each
Bore 6-inch PVC Water Pipe
60 L.F.
Drain Down Pit
1 Each
Insulated Aluminum Enclosure for Water Meter and Backflow Preventor
1 Each
Disinfection
1 L.S.
Water Connection to Existing Water Main
1 Each
SW-513 Open Sided Area Intake
2 Each
15-inch RCP Class III
24 L.F.
18-inch RCP Class III
74 L.F.
15-inch RCP Class III FES W/Apron Guards
1 Each
18-inch RCP Class III FES W/Apron Guards
1 Each
Single Campsite Outlet Post-50 Amp
37 Each
No. 2 AWG Grounding Conductor Cable, Type THW or USE
3,610 L.F.
No. 300 MCM Single Conductor Cable, Type USE
4,275 L.F.
No. 250 MCM Single Conductor Cable, Type USE
3,189 L.F.
No. 4/0 AWG Single Conductor Cable, Type USE
1,578 L.F.
No. 3/0 AWG Single Conductor Cable, Type USE
1,050 L.F.
No. 1 AWG Single Conductor Cable, Type USE
615 L.F.
No. 4 AWG Single Conductor Cable, Type USE
123 L.F.
Roadway Crossing 3-Inch Conduit Schedule 80 PVC
25 L.F.
Detectable Warning Tape, 3" Electric
3,157 L.F.
Trench, Single Circuit Secondary
3,157 L.F.
200 Amp Circuit Breaker
7 Each
400 Amp Distribution Panel
2 Each
600 Amp Distribution Panel
1 Each
400 Amp Current Transformer Cabinet
2 Each
600 Amp Current Transformer Cabinet
1 Each
Electrical Connection To Heated Water Meter Enclosure Enclosure
1 Each
Electrical Connection To Check-in Kiosk Light
1 Each
Special Backfill/Granular Base
9 Tons
5-inch Non-Reinforced PCC Sidewalk
43 S.Y.
.5-inch Expansion Joint
70 L.F.
6-inch Non-Reinforced PCC
1,445 S.Y.
7-inch Non-Reinforced PCC
659 S.Y.
Engineering Fabric
4,500 S.Y.
Class 'A' Crushed Stone
1,762 Tons
4'x4'x5.5" Reinforced PCC Fire Ring (3 of the Grills are ADA)
37 Each
Grill & Placement on Fire Ring Concrete Pad
34 Each
ADA Grill & Placement on ADA Concrete Pad
3 Each
Traffic Control
1 L.S.
Seeding, Fertilizing and Mulching
4 Acres
Temporary Seeding, Fertilizing and Mulching
1 Acres
Street Signage
1 L.S.
Handicap Parking Signage
1 L.S.
Parking Space Pavement Striping, Handicap Parking Cross Hatch Markings
This project consists of the complete replacement of the Bellevue State Park Lodge Roof. Includes removal/disposal of existing roofing material, old vent pipe removal, deck sheathing repair, roofing underlayment, new roofing material, removal/ replacement/aluminum wrapping of all fascia and rake trim, removal/disposal of existing gutters/downspouts, new 6-inch K-style gutters/downspouts with metal gutter guards and any necessary site clean-up. Installation of roofing insulation is also possible.
Contact: Bruce Flippin 515-689-8009 bruce.flippin@dnr.iowa.gov
This project consists of the removal and replacement of existing roofing/siding metal and trim work. The repair of a header on an 18' wide garage door is also included. The potential for additional work to provide a new interior column, a new 12'W X 14'H garage door, electrical service entrance/panel upgrade is also possible.
Contact: Bruce Flippin 515-689-8009 bruce.flippin@dnr.iowa.gov
HMA full depth road patches in Springbrook campground as described and specified in the project plans. Send an email to request plans and proposal form.
The lift station rehabilitation project includes the removal and replacement of 3" and 4" ductile iron piping and valves. It also includes valve vault restoration, excavation, pipe coating, and a 2" PVC drain line.
Send an email to request plans.
Contact: Jason Kruse (515) 250-3707 jason.kruse@dnr.iowa.gov