Iowa DNR
Iowa DNR
ADBNet
Water Quality Assessments
Impaired Waters List

Unnamed Tributary to Twelvemile Creek IA 05-GRA-6584

from mouth (T73N R30W Sec17 Union Co.) to dam at pond (T73N R30W Sec18 Union Co.)

Cycle
2024
Release Status
Final
Overall IR
3 - Insufficient data exist to determine whether any designated uses are met.
Trend
Unknown
Created
11/1/2023 8:14:00 AM
Updated
1/8/2024 1:10:55 PM
Use Support
Class A1
Recreation - Primary contact
Not Assessed
Class BWW1
Aquatic Life - Warm Water Type 1
WINOFI
Impairment Code
3b - Use potentially impaired based on an evaluated assessment.
Cause Magnitude
Slight
Status
Continuing
Source
Unknown: Source Unknown
Source Confidence
Low
Cycle Added
2014
Impairment Rationale
Potential Impairment
Data Source
Watershed project monitoring
Impairment Delistings
No delistings for this assessment cycle.
Documentation
Assessment Summary

The presumptive Class BWW1 use remains assessed as “WINOFI” due to violations of the dissolved oxygen criterion. All other designated uses were "not assessed."

Assessment Explanation

Data Sources:

Data Source

Data Source ID

Data Type

Data Age

Site ID

Site Name

Site Description

Iowa DNR

6

WQ

CY 2012

13880007

Unnamed Creek at 140th Street

Site 12m-7


Presumptive Class A1 - No Data


Presumptive Class BWW1 - Binomial Parameters:

Site ID

Data Source ID

Parameter Name

# Samples / # Years

Maximum Value

Mean Value

Median Value

# Acute / Chronic Violations

% Acute/ Chronic Violations

Significantly >10% Violations

Assessment Type

Support Level

13880007

6

Ammonia

7/1

4.7

1.7

1.2

0 / 2

0% / 29%

NA

Evaluated

Full

13880007

6

Dissolved oxygen

8 / 1

8.5

4

3.3

NA / 5

NA / 62%

Yes

Evaluated

WINOFI

13880007

6

pH

8 / 1

8.5

7.4

7.4

0 / NA

0% / NA

No

Evaluated

Full

13880007

6

Temperature

8 / 1

27.5

24

24.8

0 / 0

0% / 0%

No

Evaluated

Full

Monitoring and Methods
Assessment Key Dates
5/10/2012
Monitoring Start
8/9/2012
Monitoring End
Methods
150
Monitoring data more than 5 years old
200
Physical/Chemical Monitoring