Unnamed Tributary to Unnamed Tributary to Dry Run Creek IA 01-UIA-6555
from mouth (T97N R9W Sec3) to headwaters (T97N R9W Sec15) Winneshiek Co.
- Cycle
- 2022
- Release Status
- Final
- Overall IR
- 5 - Water is impaired or threatened and a TMDL is needed.
- Trend
- Unknown
- Created
- 1/11/2022 1:06:20 PM
- Updated
- 1/11/2022 1:28:35 PM
The presumptive Class A1 use was assessed as "not supported" due to levels of indicator bacteria (E. coli) that exceeded state water quality criteria. The presumptive Class BWW1 use was assessed as "fully supported" based on water quality monitoring data.
Data
Sources: Data Source Data Source ID Data Type Data Age Site ID Site Name Site Description Iowa DNR 6 WQ CY 2010-2011 15960023 Dry Run Creek Watershed Site 13a Site ID Data Source ID # Samples / # Years 2010 Geometric Mean 2011 Geometric Mean Annual Geometric Mean Violation # Violations % Violations Significantly >10% Violations Assessment Type Support Level 15960023 6 21 / 2 2625 3538 Yes 21 100% Yes Evaluated Not The monitoring conducted as part of this watershed
study included sampling for indicator bacteria (E. coli) immediately (within
24 hours) following rainfall runoff events. About half the samples in each of
2010 and 2011 were collected under such conditions. See the following journal
article for more information: Wittman et al. 2013. Evaluation of land use and
water quality in an agricultural watershed in the USA indicates multiple
sources of bacterial impairment. Environ. Monit. Assess. (2013)
185:10395-10429. Site ID Data Source ID # Samples / # Years Maximum Value Mean Value Median Value # Violations % Violations Significantly >10% Violations Assessment Type Support Level 15960023 6 20 / 2 8.2 7.9 8 0 0% No Evaluated Full Site ID Data Source ID Parameter Name # Samples / # Years Maximum Value Mean Value Median Value # Acute / Chronic Violations % Acute/ Chronic Violations Significantly >10% Violations Assessment Type Support Level 15960023 6 Ammonia 19 / 2 0.39 0.1 0.05 0 / 0 0% / 0% No Evaluated Full 15960023 6 Dissolved oxygen 23 / 2 12.7 8.2 8.6 NA / 2 NA / 9% No Evaluated Full 15960023 6 pH 20 / 2 8.2 7.9 8 0 / NA 0% / NA No Evaluated Full 15960023 6 Temperature 23 / 2 21 14.8 14.8 0 / 0 0% / 0% No Evaluated Full
Presumptive Class A1 - Indicator Bacteria:
Presumptive Class A1 - pH:
Presumptive Class BWW1 - Conventional Parameters: