Iowa DNR
Iowa DNR
ADBNet
Water Quality Assessments
Impaired Waters List

Cedar Lake IA 04-LDM-1101

Madison County S19T76NR27W near Winterset.

Cycle
2024
Release Status
Final
Overall IR
2 - Some of the designated uses are met but there is insufficient data to determine if remaining designated uses are met.
Trophic
Unknown
Trend
Stable
Created
11/1/2023 8:13:06 AM
Updated
1/24/2024 3:37:50 PM
Use Support
Class BLW
Aquatic Life - Lakes and wetlands
Fully Supported
Class C
Drinking Water -
Fully Supported
Class HH
Human Health -
Not Assessed
Impairment Delistings
No delistings for this assessment cycle.
Documentation
Assessment Summary

The Class BLW use was assessed (monitored) as "fully supported." The Class C use was assessed (monitored) as "fully supported" based on water quality monitoring data and drinking water compliance monitoring required by the DNR. All other designated uses were “not assessed.” Note: A TMDL for nitrate at Cedar Lake was prepared by DNR and approved by EPA in 2005. A TMDL for atrazine at Cedar Lake was prepared by DNR and approved by EPA in 2010.

Assessment Explanation

Data Sources:

Data Source

Data Source ID

Data Type

Data Age

Site ID

Site Name

Site Description

Iowa DNR

6

WQ

CY 2018-2022

22610005

Cedar Lake

Class BLW - Binomial Parameters:

Site ID

Data Source ID

Parameter Name

# Samples / # Years

Minimum Value

Maximum Value

Mean Value

# Violations

# Acute / Chronic Violations

Violations needed for impairment

Violates Significantly >10% Rule?

Assessment Type

Support Level

22610005

6

Dissolved Oxygen

15 / 5

5.1

15.2

8.4

0

NA / NA

4

NO

Mon

Full

22610005

6

pH

12 / 4

8.1

9

8.5

0

NA / NA

4

NO

Mon

Full

22610005

6

Temperature

15 / 5

20.4

28

24.8

0

NA / NA

4

NO

Mon

Full

Class BLW - Toxic Parameters:

Site ID

Data Source ID

Parameter Name

# Samples / # Years

Maximum Value

Mean Value

Median Value

# Acute / Chronic Violations

>1 Acute / Chronic Violation

Assessment Type

Support Level

22610005

6

Ammonia

12 / 4

0.072

0.04

0.03

0 / 0

NO

Mon

Full

Class C - Binomial Parameters:

Site ID

Data Source ID

Parameter Name

# Samples / # Years

Minimum Value

Maximum Value

Mean Value

Median Value

# Violations

Violates Significantly >10% Rule?

Assessment Type

Support Level

22610005

6

Inorganic nitrogen (nitrate and nitrite)

14 / 5

0.03

6.34

2.48

1.64

0

NO

Mon

Full

22610005

6

pH

12 / 4

8.1

9

8.5

8.5

0

NO

Mon

Full


Class C - Iowa Drinking Water Compliance Report:

Compliance monitoring required by the Iowa DNR Water Supply Operations and Engineering Sections did not show violations of finished water caused by source water at the Winterset Municipal Waterworks facility during the 2020-22 monitoring period. The results of compliance monitoring as reported in annual compliance reports are available at the following location at the Iowa DNR’s home page: https://www.iowadnr.gov/Environmental-Protection/Water-Quality/Water-Supply-Engineering/Annual-Compliance-Report.

Class HH - No Data

Monitoring and Methods
Assessment Key Dates
9/7/2022
Monitoring End
5/29/2018
Monitoring Start
6/6/2005
TMDL Completed
3/19/2010
TMDL Completed
Methods
200
Physical/Chemical Monitoring
275
Drinking water compliance reports