West Lake (Osceola) IA 04-LDM-1082
Clarke County S13T72NR26W approx 2 mi W of Osceola.
- Cycle
- 2026
- Current Phase
- Public Comment
- Overall IR
- 5 - Water is impaired or threatened and a TMDL is needed.
- Trophic
- Eutrophic
- Trend
- Stable
- Created
- 10/27/2025 3:09:53 PM
- Updated
- 12/29/2025 2:55:23 PM
The Class BLW use was assessed (monitored) as “not supported” due to violations of the Class BLW criterion for DO. The Class C use was assessed (monitored) as "fully supported" based on water quality monitoring data and drinking water compliance monitoring required by the DNR. All other designated uses are “not assessed.” Note: A TMDL for atrazine at West Lake (Osceola) was prepared by DNR and approved by EPA in 2002. Because not all Section 303(d) impairments identified for the current assessment/listing cycle (dissolved oxygen) are addressed by the TMDL, this waterbody was placed in IR Category 5a (impaired; TMDL needed).
Data Sources: Data Source Data Source ID Data Type Data Age Site ID Site
Name Site
Description Iowa DNR 6 WQ CY 2020-2024 22200002 West
Lake Osceola
Osceola Water Works 27 WQ CY 2022-2022 99990204 West
Lake Public
Water Supplies Class BLW - Binomial Parameters: Site ID Data Source ID Parameter Name # Samples / # Years Minimum Value Maximum Value Mean Value # Violations # Acute / Chronic Violations Violations needed for impairment Violates Significantly >10% Rule? Assessment Type Support Level 22200002 6 Dissolved Oxygen 14 / 5 2.6 8.8 6.2 4 NA / NA 4 YES MONITORED NOT 22200002 6 pH 15 / 5 6.8 8.8 8 0 NA / NA 4 NO MONITORED FULL 22200002 6 Temperature 15 / 5 21.2 27.9 24.1 0 NA / NA 4 NO MONITORED FULL Class BLW - Lake Planktonic Cyanobacteria: Site ID Data Source ID # Samples Maximum Cyanobacteria Wet Mass Maximum Cyanobacteria % Composition Median Cyanobacteria Wet Mass Median Cyanobacteria % Composition Median Cyanobacteria Concentration = 75th Percentile Assessment Type Support Level 22200002 6 3 4.9414 92.32% 0.2378 13.33% NO EVALUATED NA Class BLW - Toxic Parameters: Site ID Data Source ID Parameter Name # Samples / # Years Maximum Value Mean Value Median Value # Acute / Chronic Violations >1 Acute / Chronic Violation Assessment Type Support Level 22200002 6 Ammonia 15 / 5 0.472 0.12 0.05 0 / 0 NO MONITORED FULL Class C - Binomial Parameters: Site ID Data Source ID Parameter Name # Samples / # Years Minimum Value Maximum Value Mean Value Median Value # Violations Violates Significantly >10% Rule? Assessment Type Support Level 99990204 27 Fluoride 1065 / 3 20 530 282 270 0 NO MONITORED FULL 22200002 6 Inorganic nitrogen (nitrate and nitrite) 14 / 5 0.03 1.52 0.31 0.14 0 NO MONITORED FULL 22200002 6 pH 15 / 5 6.8 8.8 8 8 0 NO MONITORED FULL Class C - Iowa Drinking Water Compliance Report: Compliance monitoring required by the Iowa DNR Water Supply
Operations and Engineering Sections did not show violations of finished water
that were caused by source water at the Osceola Water Works facility during the
2022-24 monitoring period. The violations reported were related to plant
operations. The results of compliance monitoring as reported in annual
compliance reports are available at the following location at the Iowa DNR’s
home page: https://www.iowadnr.gov/Environmental-Protection/Water-Quality/Water-Supply-Engineering/Annual-Compliance-Report. Class HH – The previous Fish Tissue monitoring assessment was
removed based on the age of the data